P730 Differential Pressure Gauge Capsule Type

 

CASE DIAMETER

6”(150 mm)

ACCURACY CLASS PER EN 837- 3/6

1,6

SCALE RANGES PER EN 837- 3/5

0...6 to 0...250 mbar

Or equivalent other units of pressure

OVERP RESSURE SAFETY

No over pressure safety when pressure applied at one side only

STATIC PRESSURE RATING

250 mbar

OPERATING TEMPERATURE

Ambient : – 25 to 65°C

Process fluid : max 65°C

TEMPERATURE ERROR

When temperature of the pressure element deviates from +20°C :

Rising temperature : + 0.6% / 10°C of true scale value

Falling temperature : - 0.6%/ 10°C of true scale value

 

STANDARD FEATURES PROCESS CONNECTION

Material : stainless steel AISI 316

Thread size : 2 x 1/2" NPT or BSP-M Lower or back

PRESSURE ELEMENT

Capsule stainless steel AISI 316

SEALING RING

FKM(Viton)

MOVEMENT

Nickel-plated brass

DIAL

Aluminum with black markings on white background

POINTER

Black aluminum pointer

CASE AND RING

Material : stainless steel AISI 316

Style : bayonet ring

Protection class : IP67–EN 60529/IEC 529

WINDOW

Acrylic glass 0.16”(4mm)

GASKET

Neoprene rubber

MOUNTING

Stem mounting

Panel mounting with front flange

Surface mounting with back flange

Pressure entries identified (+) and (-)

(+) high pressure

(-) low pressure

OPTIONAL EXTRAS

Other threaded process connection

Three way or five way valve manifold

Customer designed dial

Safety glass window

 

Print | Sitemap