CASE DIAMETER
2.5”(63 mm)
ACCURACY CLASS PER EN 837-1/6
1.6
SCALE RANGES PER EN 837-1/5
0…1 to 0…1000bar
Or equivalent other units of pressure or vacuum
WORKING PRESSURE
Continuous service up to maximum rating
Intermittent service up to1.3 times maximum rating for ranges up to 60 bar;
up to1.15 times for ranges over 100 bar
Fluctuating up to 90 % of maximum rating only
OPERATING TEMPERATURE
Ambient:
- 40 / + 65°C
Process fluid : 100°C max
TEMPERATUR EERROR
When temperature of the pressure element deviates from +20°C:
Rising temperature : +0.4 % / 10°C of true scale value
Falling temperature: - 0.4 % / 10°C of true scale value
STANDARD FEATURES
PROCESS CONNECTION
Material : stainless steel AISI 316
Thread size : 1/4” BSP or NPT–M Lower or back
PRESSURE ELEMENT
AISI 316L stainless steel
-1 to 60 bar : C - type
100 to1000 bar : Helical - type
MOVEMENT
Stainless steel AISI304
DIAL
Aluminum with black markings on white background
Dial arc 270°C
POINTER
Black aluminum pointer
CASE AND RING
AISI 304 stainless steel
Bayonet ring style
Protection class : IP 65–EN60529/IEC 529
WINDOW
Plexiglas
GASKET
Neoprene rubber
MOUNTING
Stem mounting
Panel mounting with front flange or U-clamp connection
Surface mounting with black flange
OPTIONAL EXTRAS
Other process connection
Case and ring material stainless steel AISI 316
Case and ring crimped
Glycerin filled case (+15to+ 65 °C)
Silicon oil filled case (-45to+100°C)
Other liquids such as compatible
with food processes or for oxygen service(Galden=Per fluorinated poly ethers) are available up on request
Safety glass or Plain glass
Diaphragm seals (see DS data sheet)
Oxygen service
Maximum reading pointer
CASE DIAMETER
4”(100) , 6”(150mm) and 10"(250 mm)
ACCURACY CLASS
1.0
SCALERANGE
0…0.6 to 0…1600 bar
Or equivalent other units of pressure or vacuum ranges
PRESSURE LIMITATION
Continuous service :
Steady pressure up to F.S. value
Fluctuating pressure up to 90% F.S. value
Short time1.3 x F.S. value for range up to100bar and 1.15 x F.S. for range over 100bar
OPERATING TEMPERATURE
Ambient :
- 40 /+ 60°C without liquid filling
-20/+60°C with liquid filling
Medium:
+200°C max. without liquid filling
+100°C max. with liquid filling
TEMPERATURE EFFECT
When temperature of the measuring system deviates from reference temperature (+20°C) max.
error ± 0.4 % /10K of true scale value
STANDARD FEATURES
PROCESS CONNECTION
AISI 316L stainless steel
Thread size for lower or back mounting : 1/2 ”BSP or NPT
PRESSURE ELEMENT
AISI 316L stainless steel
< 100 bar : C - type
> 100bar : Helical type
MOVEMENT
Stainless steel , with over and under load stop
Free zero
MEASURING SYSTEM
Bourdon tube and socket are TIG-welded : one integral unit
DIAL
Aluminum with black markings on white background
Dial arc 270°C
POINTER
Adjustable , black aluminum
CASE AND RING
AISI 304 stainless steel
Bayonet ring style
With pressure relief in case back
Filling plug on top(to be used also to vent case before use for range <16bar)
INGRESS PROTECTION
IP 65 – EN 60529/IEC 529
WINDOW
Safety glass o.16”(4mm) thickness
GASKET
Neoprene rubber
LIQUID FILLING
(modelP600.5)
Glycerine99.7%
(ambient temperature +15/+60 °C)
OPTIONAL EXTRAS
Other process connection
Case and ring AISI 316 stainless steel
Monel measuring system
Surface mounting with back flange
Panel mounting with front flange
U - clamp connection
Silicon oil case filling (ambient temperature – 40/+60°C)
Other liquids are available up on request (such as compatible with food processes or for oxygen service)
Electric contacts (see CE data sheet) (1)
Plastic window (not for ATEX)
Diaphragm seals (see DS data sheet)
Oxygen service
Customer designed dials
Dial tag marking
Maximum reading pointer
Movement with dampening jelly
Screw restrictor
Accuracy class 0.5
Version per ATEX ExII2GDc
Note:
(1)ATEX version : only 4”(100),high case, contact under dial, inductive contact only